GE PT925DN Convection Oven User Manual


 
Listed by
Underwriters
Laboratories
For answers to your Monogram,
®
GE Profile
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
Specification Revised 4/09
220244
PT925DN
GE Profile
30" Built-In Single/Double Convection Wall Oven
KW Rating
240V
3.9
208V
2.9
Breaker Size
240V
20 Amps
208V
20 Amps
Dimensions and Installation Information (in inches)
Most 30” Wall Cabinets can be used with this unit.
Note: These ovens are not approved for
stackable installations. Cabinets installed
adjacent to wall ovens must have an adhesion
spec of at least a 194°F temperature rating.
Door handle protrudes 3" from door face. Cabinets
and drawers on adjacent 45° and 90° walls should
be placed to avoid interference with the handle.
Electric wall ovens are not approved for
installation with a plug and receptacle. They
must be hard wired in accordance with
installation instructions.
Installation Information: Before installing, consult
installation instructions packed with product for
current dimensional data.
Side-by-side installations require at least 2"
between cutouts.
CUTOUT
HEIGHT
27 1/4" MIN.
27 5/16" MAX.
CUTOUT
WIDTH
28 1/2" MIN.
28 5/8" MAX.
5"
22" TO
BOTTOM OF
JUNCTION BOX
JUNCTION
B
LOCATIO
N
RECOMMENDED
CUTOUT
LOCATION
32 1/2"
FROM THE
FLOOR
CABINET
WIDTH
30"
ALLOW 11/16" FOR
OVERLAP OF THE
OVEN OVER SIDE
EDGES OF CUTOUT
THE OPENING
BETWEEN INSIDE
WALLS MUST
BE AT LEAST
28 1/2"WIDE
ALLOW 1" FOR
OVERLAP
ON OVEN TOP
AND BOTTOM
OF CUTOUT
21"
ALLOW A MINIMUM
F
21" FOR CLEARANCE
ADJACENT CORNERS,
R
AWERS, WALLS ETC.
N
THE DOOR IS OPENED.
Allow 11/16
(1.75 cm) for
overlap of oven
over side edges
of cutout
Cutout
Width
28 1/2
(72.4 cm)
Min.
28 5/8
(72.7 cm)
Max.
15
(38.1 cm)
Cabinet
Width
30
(76.2 cm)
Allow a minimum
of 15” (38.1 cm) for
clearance to adjacent
corners, drawers,
walls, etc. when
door is open
Allow 1” (2.5 cm)
minimum for
overlap of oven
top and 1 1/4”
(3.2 cm) overlap
of oven bottom
of cutout
Recommended
cutout
location from
floor 26 1/2”
(67.3 cm) max
Opening
Between
Inside Walls
Must Be
At Least
28 1/2”
(72.4 cm)
Wide
Junction Box
Location
(junction box
may be
located in
adjacent
cabinet)
9 1/2
(12.7 cm)
Max.
Cutout
Height
27 1/4
(69.2 cm) Min.
27 5/16
(69.4 cm) Max.
22 (55.9 cm)
Min. to
Bottom of
Junction Box
C
L
2 x 4 or
equivalent
runners
Suitable
bracing
to support
runners
21-5/8"
over centerline
of cabinet
(must support 275 lbs.)
Cutout width
28-1/2'' MIN.
28-5/8'' MAX.
29-3/4
C
30
Recommended
cutout location
32-1/2"
from floor
21
Junction
box
location
Allow minimum of 21'' for clearance
to adjacent corners, drawers, walls, or etc.
A=Allow 1" overlap of oven over top and bottom edges of cutout.
B=Allow 11/16"–3/4" for overlap of oven over side edges of cutout.
C=28-1/4" without trim and 28-3/4" with trim.
Conduit
(72"
long)
5
27-1/4'' MIN.
27-5/16'' MAX.
Cutout height
A
B
23-1/2'' MIN.
Cutout depth
22'' MIN.