UltraViolet Devices Ultravoilet Lamp System Indoor Furnishings User Manual


 
vb:
uv_>
V-RAY
V-RAY
™ SUS
SUS
4-lamp sizes (12", 21", 33" and 61")
Lowest mercury content available
UV output regulated to keep levels
within ACGIH and NIOSH exposure
guidelines (patent pending) thus
–Extending lamp life and
–Ensuring safe exposure limits for
room occupants or materials
UL recognized components, ETL Listed
Ideal for any vertical or horizontal
system
Ease of installation – Simple Lamp
Clasps (magnetic Lamp Clasp optional)
Single point electrical connection
UVC resistant materials
Screw terminals for easy field wiring
Remotely located power source
offering ease of installation and
mounting options
Restores air handling unit to near
optimal operating capacities
Can lower energy costs for restored
systems
Reduces costly maintenance and
cleaning programs
Eliminates foul system odors (dirty
sock syndrome)
Has one of the lowest ownership
costs in the industry
Improves indoor air quality by
destroying system microbes
Will not harm building occupants,
equipment or furnishings
One-year warranty on both the fixture
and the lamp
All ALTRU-V products are designed to transform HVAC efficiency, maintenance
and longevity. By applying real science, the relentless cleaning power of UV and
the most affordable products by UVDI, optimal HVAC maintenance solutions can
replace outdated mechanical and chemical cleanings that can be both costly and
dangerous and shorten equipment life. The results are lower operating costs,
safer environments for maintenance personnel and occupants, as well as
documented cleaner air.
ALTRU-V’s
V-Ray provides unique electronically controlled energy output (patent
pending) at registers and grills to meet acceptable levels as recommended by the
National Institute for Occupational Safety and Health (NIOSH) and the American
Conference of Governmental Industrial Hygienists (ACGIH), yet it delivers the
proper amount of energy necessary to control the growth of micro-organisms such
as mold and bacteria.
Easily Installed into hard to access systems delivering continuous
irradiation for improved heat exchange efficiency while reducing
foul odor, drain pain overflows and expensive coil cleanings!
REPRESENTED BY:
UVC Fixturing Fixturing consists of a
lamp, lamp clasps, UVC resistant wiring
harness, power supply and power supply
housing.
Lamps Each lamp contains no more
than 5 milligrams of mercury. Lamp life
is 9000 hours with no more than a 20%
output loss at the end of the lamps life.
Lamps are constructed with UVC resistant
bases and do not produce ozone. When
used for surface irradiation, the lamp
selected will be equal to or no less than
90% of the coil width.
Irradiation Fixtureless lamps are to be
installed in sufficient quantity and in such
a manner as to provide an equal distribu-
tion of UVC energy. When installed, the
UVC energy produced will be of the lowest
possible reflected and shadowed losses.
Note: the applied energy and its distribu-
tion shall be verifiable using third
party algorithms.
Intensity The minimal UVC energy
striking a surface is sufficient to continu-
ously destroy a monolayer of mold and
bacteria in less than six hours when at
55135°F. The third party modeling shall
be available to determine the destruction
time for at least four of the most common
fan coil surface microbes.
Lamp Clasp Lamp Clasps may be
permanently or magnetically affixed to the
irradiated cavity. They are constructed of
high memory, plated steel for maximum
holding power and corrosion resistance.
Lamp Wire Is of sufficient length to
facilitate lamp connection to a remotely
located ballast. It includes a grommet to
facilitate safe passage through sheet metal
and into the ballast housing. Lamps are
capable of being mounted anywhere in the
system and/or as shown on the plans.
Power Supply Power supplies are of
the high efficiency electronic type, matched
to the lamp and designed to optimize UVC
photon production and reliability. They are
UL Listed and labeled for use in air-streams
of 55135°F. They are capable of pro-
ducing the specified output and organism
destruction as listed under Irradiation and
Intensity above at no more than 13 Watts
of power consumption for each square foot
of treated, cross sectional area.
Installation Fixturing are electrically
terminated to within factory supplied ballast
housings to meet NEC and local codes.
Lamps should be mounted to irradiate the
intended surface(s) as well as all of the
available line of sight airstream by proper
placement and incident angle reflection.
Safety To protect maintenance
personnel, all access panels and doors
to the UVC assembly and/or within view
of the UVC assembly must include mechan-
ical interlock switche(s) to insure that the
UVC assembly will be de-energized when
any of these accesses are opened.
1. V-Ray Bulb Lengths: 61*, 36, 24 and 12*.
2. V-Ray Magnetic Clip
1
2
ALTRU-V (A Division of UVDI)
26145 Technology Drive
Valencia, CA 91355
Tel 877-PUREUVC
(877-787-3882)
Tel 661-295-8140
Fax 661-257-4698
www.altruv.com
Specifications subject to change without notice.
V-Ray SUS: 12”, 21”, 33”, 61” Lamp Sizes.
Copyright 2004 UVDI. ALTRU-V and V-Ray SUS are trademarks owned by UVDI. Patent Pending. 23-1004 Rev A
Model No. Description Lamp Dim. Electrical Weight P/N
VRSUS 12 V-Ray UVC Fixture 12” * 100–277Vac, 50-60 Hz, 11 Watts 3 lbs. 23-1012
VRSUS 21 V-Ray UVC Fixture 21” 100–277Vac, 50-60 Hz, 15 Watts 3 lbs. 23-1021
VRSUS 33 V-Ray UVC Fixture 33” 100–277Vac, 50-60 Hz, 21 Watts 3 lbs. 23-1033
VRSUS 61 V-Ray UVC Fixture 61” * 100–277Vac, 50-60 Hz, 31 Watts 5 lbs. 23-1061
VR MC V-Ray UVMagClasp (Pair) 0.5 lbs. 23-1063
* The V-Ray 12” and 64” units are non-inventory items subject to varying lead times.
Hg-LAMP CONTAINS MERCURY. Manage in Accord with
Disposal Laws. See: www.lamprecycle.org or call 877-PUREUVC