White Rodgers 1C30(W) Thermostat User Manual


 
This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.
To prevent electrical shock and/or equipment
damage, disconnect electric power to system, at
main fuse or circuit breaker box, until installation
is complete.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will burn
out heat anticipator and could cause personal
injury and/or property damage.
Do not use on circuits exceeding 30 volts. Higher
voltage will damage control and could cause
shock or fire hazard.
Printed in U.S.A.
WHITE-RODGERS
R
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS RD., ST. LOUIS, MO. 63123
(314) 577-1300, Fax (314) 577-1517
9999 HWY. 48, MARKHAM, ONT. L3P 3J3
(905) 475-4653, FAX (905) 475-4625
PART NO. 37-5584A
Replaces 37-9599A
9531
Operator: Save these instructions for future use!
This low voltage thermostat is designed to provide conve-
nient control of the heating system. To provide greater
room comfort, the sensitive spiral bimetal is combined
with an adjustable heating anticipator to provide maxi-
mum comfort.
ATTENTION!
This product does not contain mercury. However, this product may replace a unit which contains mercury. Do not open mercury cells. If a
cell becomes damaged, do not touch any spilled mercury. Wearing non-absorbent gloves, take up the spilled mercury with sand or other
absorbent material and place into a container which can be sealed. If a cell becomes damaged, the unit should be discarded. Mercury must
not be discarded in household trash. When the unit this product is replacing is to be discarded, place in a suitable container and return to
us at WHITE-RODGERS.
If in doubt about whether your wiring is millivolt, line, or low
voltage, have it inspected by a qualified heating and air
conditioning contractor, electrician, or someone familiar
with basic electricity and wiring.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical
codes and ordinances.
PRECAUTIONS
1C30(W) / 1D30(W)
Low Voltage Heating Thermostat
INSTALLATION INSTRUCTIONS
1D30
1C30
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
CONTENTS
Description .......................................................... 1
Precautions ......................................................... 1
Specifications ......................................................2
Installation...........................................................2
Select Thermostat Location
Route Wires to Location
Attach Thermostat to Wall
Operation & Maintenance ................................... 3
Adjusting Heat Anticipator
Calibrating Thermostat
CAUTION
!
WARNING
!