Mitsubishi Electronics PUHY-P168TSHMU-A Heat Pump User Manual


 
Job Name: Location:
Drawing Reference: Schedule No.
System No.: Date:
Specications System Module 1 Module 2
Unit Type PUHY-P168TSHMU-A PUHY-P96THMU-A PUHY-P72THMU-A
Nominal Cooling Capacity Btu/h 168,000 96,000 72,000
Nominal Heating Capacity Btu/h 188,000 108,000 80,000
External Dimensions (H x W x D) In. / mm Refer to Module Data
65 x 36-1/4 x 29-15/16 /
1,650 x 920 x 760
65 x 36-1/4 x 29-15/16 /
1,650 x 920 x 760
Net Weight Lbs. / kg 882 / 400 441 / 200 441 / 200
Electrical Power Requirements Voltage, Phase, Hertz Refer to Module Data** 208/230V, 3-phase, 60Hz
Cooling Power Input kW 14.11
Refer to System Data
Heating Power Input kW 14.73
Cooling Current (208/230V) A 43.5 / 39.3
Refer to System Data
Heating Current (208/230V) A 45.4 / 41.0
Minimum Circuit Ampacity
(MCA)**
A Refer to Module Data** 35 / 32** 23 / 21**
Maximum Overcurrent
Protection (MOCP)**
A Refer to Module Data** 40 / 40** 30 / 30**
Piping Diameter
Refer to System Data
From Twinning Kit to Indoor Units
(Brazed) (In. / mm)
Liquid (High Pressure) 5/8 / 15.88
Gas (Low Pressure) 1-1/8 / 28.58
From Modules to Twinning Kit
(Brazed) (In. / mm)
Liquid (High Pressure)
Refer to Module Data
3/8 / 9.52 3/8 / 9.52
Gas (Low Pressure) 7/8 / 22.2 3/4 / 19.05
Indoor Unit
Total Capacity 50 to 130% of ODUs
Refer to System Data
Model / Quantity P06 ~ P96 / 1 to 36
Sound Pressure Levels dB(A) 61.0 58.0 58.0
Fan
Refer to Module Data
Type x Quantity Propeller Fan x 1 Propeller Fan x 1
Airow Rate CFM 7,050 7,050
Direct-drive Inverter Motor Output kW 0.92 0.92
Compressor Operating Range 8% to 100% Refer to System Data
Compressor Type x Quantity
Refer to Module Data
Inverter-driven Scroll Hermetic x 1 Inverter-driven Scroll Hermetic x 1
Compressor Motor Output kW 6.8 5.1
Compressor Crankcase Heater kW 0.051 0.051
Refrigerant
Refer to Module Data
R410A
Lubricant MEL32
High-pressure Protection Device
Refer to Module Data
601 psi / 4.15 MPa 601 psi / 4.15 MPa
Compressor / Fan Protection Device Overheat Protection / Thermal Switch Overheat Protection / Thermal Switch
Inverter Protection Device Overheat / Overcurrent Protection Overheat / Overcurrent Protection
Blue Fin Anti-corrosion Protection: Cellulose- and polyurethane-resin coating treatment applied to condenser coil that protects it from air contaminants;
≥1μm thick; Salt Spray Test Method - no unusual rust development to 480 hours.
Outdoor Unit: 14-TON PUHY-P168TSHMU-A
(Consists of One PUHY-P96THMU-A, One PUHY-P72THMU-A, and One CMY-Y100VBK2 Twinning Kit)
OUTDOOR VRFZ HEAT PUMP SYSTEM FEATURES
• 3-phase, 208/230V systems
• Modular variable refrigerant ow zoning (VRFZ) systems;
smaller capacity units can be piped together to form a single,
large-capacity two-pipe system
• Compact size for each outdoor module; can be transported
through standard-sized doorways for installation
• Required Twinning Kit allows for easy eld piping connection
• Selectable fan static, 0.12 or 0.24"WG external static
pressure; factory set to 0"WG
• Maximum Total Refrigerant Piping Length: 3,280'; Maximum
Refrigerant Line Length: 541'; Maximum Control Wiring
Length: 1,650'
• Connects to CITY MULTI indoor units; controlled via
CITY MULTI Controls Network (CMCN)
• External finish: Pre-coated Galvanized-steel Sheets
• Operating Temperature Range
Cooling (Outdoor): 23° ~ 109°F (-5° ~ +43°C) DB
Heating (Outdoor): -4° ~ +60°F (-20° ~ +16°C) WB
** Each individual module requires a separate electrical connection. Reference electrical data for each individual module.
PUHY-P72THMU-A
OPTIONAL PARTS
□ Twinning Kit*.…………………………………...…….CMY-Y100VBK2
□ T-Branch Joint (≤ 72,000 Btu/h)………………..........CMY-Y102S-G2
□ T-Branch Joint (≤ 144,000 Btu/h)……………….…....CMY-Y102L-G2
□ T-Branch Joint (≤ 234,000 Btu/h)………………..........CMY-Y202-G2
□ Header (4-Branch; ≤ 72,000 Btu/h)........………………CMY-Y104-G
□ Header (8-Branch; ≤ 144,000 Btu/h)......………………CMY-Y108-G
□ Header (10-Branch; ≤ 234,000 Btu/h)....……………….CMY-Y1010-G
* Twinning Kit is necessary to combine the refrigerant ows of the
modules and is included in the outdoor unit set.
PUHY-P96THMU-A